Variation of strength and stiffness of fibre reinforced polymer reinforcing bars with temperature

Y. C. Wang, V. Kodur

Research output: Contribution to journalArticlepeer-review

82 Scopus citations

Abstract

This paper presents the results of tensile mechanical properties of FRP reinforcement bars, used as internal reinforcement in concrete structures, at elevated temperatures. Detailed experimental studies were conducted to determine the strength and stiffness properties of FRP bars at elevated temperatures. Two types of FRP bars namely: carbon fibre reinforced polyester bars of 9.5 mm diameter and glass fibre reinforced polyester bars of 9.5 mm and 12.7 mm diameter were considered. For comparison, conventional steel reinforcement bars of 10 mm and 15 mm diameter were also tested. Data from the experiments was used to illustrate the comparative variation of tensile strength and stiffness of different types of FRP reinforcing bars with traditional steel reinforcing bars. Also, results from the strength tests were used to show that temperatures of about 325 °C and 250 °C appear to be critical (in terms of strength) for GFRP and CFRP reinforcing bars, respectively. A case study is presented to illustrate the application of critical temperatures for evaluating the fire performance of FRP-reinforced concrete slabs.

Original languageEnglish
Pages (from-to)864-874
Number of pages11
JournalCement and Concrete Composites
Volume27
Issue number9-10
DOIs
StatePublished - Oct 2005

Keywords

  • Critical temperature
  • Elevated temperatures
  • Fibre reinforced plastics
  • Fire resistance
  • Mechanical properties
  • Stiffness
  • Strength
  • Tests

Fingerprint

Dive into the research topics of 'Variation of strength and stiffness of fibre reinforced polymer reinforcing bars with temperature'. Together they form a unique fingerprint.

Cite this