Skip to main navigation Skip to search Skip to main content

Thermal insulation performance of wall-to-floor joints in precast concrete sandwich panel systems for off-site construction of apartment buildings

Research output: Contribution to journal › Article › peer-review

2 Scopus citations

Abstract

In this study, the thermal insulation performance of exterior wall-to-floor joints in precast concrete (PC) sandwich panel systems for off-site construction of load-bearing wall-type apartment buildings was evaluated. Three-dimensional steady-state heat transfer simulations were conducted to assess the combined effects of linear and point thermal bridges. The analysis focused on mid-layer insulation thickness, shear connector material, insulation performance, and joint detailing. The results revealed that for a mid-layer insulation thickness of 50 mm, the effective U-value decreased by 18.6%, 22.6%, and 25.7% for steel, stainless steel, and glass fiber-reinforced polymer (GFRP) connectors, respectively, compared with a conventional PC single-wall panel. For steel and stainless-steel connectors, further increases in mid-layer thickness led to performance deterioration due to intensified point thermal bridging caused by longer and denser connectors. In contrast, owing to their low thermal conductivity, GFRP connectors maintained continuous performance improvement up to a mid-layer thickness of 190 mm, indicating their effectiveness in mitigating thermal bridge in highly insulated sandwich panels. Parametric analyses revealed connector thermal conductivity thresholds, below which increasing insulation thickness did not cause deterioration. High-performance insulation materials reduced total insulation thickness while maintaining or slightly improving thermal performance. Improved wall-to-floor joint detailing further reduced effective U-values. Mock-up tests using a calibrated hot box method validated the simulation results. The experimental results agreed well with the numerical predictions, confirming the reliability of the proposed approach. These findings highlight the importance of considering both insulation configuration and connector properties in the thermal design of PC sandwich panel systems for high-performance apartment buildings.

Original languageEnglish
Article number117743
JournalEnergy and Buildings
Volume367
DOIs
StatePublished - 15 Sep 2026

Bibliographical note

Publisher Copyright:
© 2026 Elsevier B.V.

Keywords

  • Apartment buildings
  • Insulation
  • Load-bearing wall type structure
  • Precast concrete sandwich panel
  • Thermal bridge

Fingerprint

Dive into the research topics of 'Thermal insulation performance of wall-to-floor joints in precast concrete sandwich panel systems for off-site construction of apartment buildings'. Together they form a unique fingerprint.