TY - JOUR
T1 - The effect of tourniquet deflation on hemodynamics and regional cerebral oxygen saturation in aged patients undergoing total knee replacement surgery
AU - Song, Inkyung
AU - Kim, Dong Yeon
AU - Kim, Youn Jin
PY - 2012/11
Y1 - 2012/11
N2 - Background: Inflation and deflation of a pneumatic tourniquet used in total knee replacement surgery induces various changes in patient's hemodynamic and metabolic status, which may result in serious complications, especially in aged patients. Near-infrared spectroscopy (NIRS) is a monitoring device designed to estimate the regional cerebral oxygen saturation. We evaluated the effect of tourniquet deflation on hemodynamics and regional cerebral oxygen saturation in aged patients undergoing total knee replacement surgery, using NIRS. Methods: Twenty-eight American Society of Anesthesiologists physical status I or II patients, over the age of sixtyfive years undergoing total knee replacement surgery, were included. Under general anesthesia, the mean arterial pressure (MAP), heart rate (HR), cardiac output (CO), stroke volume (SV), and regional cerebral oxygen saturation (rSO2) were recorded before induction of anesthesia and every 2 min after tourniquet deflation for 20 min. Arterial blood gas analysis was performed 5 min before, in addition to 0, and 10 min after tourniquet deflation. Results: The decrease of rSO2 was not significant during 20-min deflation period. MAP, CO and SV showed significant decrease during 2 to 12, 4 to 6 and 2 to 6-min period after tourniquet deflation, respectively (P < 0.05). There was no relationship between a maximal decrease of MAP and rSO2. Conclusions: In aged patients undergoing total knee replacement surgery under general anesthesia, tourniquet deflation caused significant changes in hemodynamic and metabolic status, but not in regional cerebral oxygen saturation. It is recommended to monitor neurologic status, as well as hemodynamic and metabolic status to avoid serious complications, especially in aged patients.
AB - Background: Inflation and deflation of a pneumatic tourniquet used in total knee replacement surgery induces various changes in patient's hemodynamic and metabolic status, which may result in serious complications, especially in aged patients. Near-infrared spectroscopy (NIRS) is a monitoring device designed to estimate the regional cerebral oxygen saturation. We evaluated the effect of tourniquet deflation on hemodynamics and regional cerebral oxygen saturation in aged patients undergoing total knee replacement surgery, using NIRS. Methods: Twenty-eight American Society of Anesthesiologists physical status I or II patients, over the age of sixtyfive years undergoing total knee replacement surgery, were included. Under general anesthesia, the mean arterial pressure (MAP), heart rate (HR), cardiac output (CO), stroke volume (SV), and regional cerebral oxygen saturation (rSO2) were recorded before induction of anesthesia and every 2 min after tourniquet deflation for 20 min. Arterial blood gas analysis was performed 5 min before, in addition to 0, and 10 min after tourniquet deflation. Results: The decrease of rSO2 was not significant during 20-min deflation period. MAP, CO and SV showed significant decrease during 2 to 12, 4 to 6 and 2 to 6-min period after tourniquet deflation, respectively (P < 0.05). There was no relationship between a maximal decrease of MAP and rSO2. Conclusions: In aged patients undergoing total knee replacement surgery under general anesthesia, tourniquet deflation caused significant changes in hemodynamic and metabolic status, but not in regional cerebral oxygen saturation. It is recommended to monitor neurologic status, as well as hemodynamic and metabolic status to avoid serious complications, especially in aged patients.
KW - Aged
KW - Hemodynamics
KW - Near-infrared spectroscopy
KW - Tourniquet
UR - http://www.scopus.com/inward/record.url?scp=84870489638&partnerID=8YFLogxK
U2 - 10.4097/kjae.2012.63.5.425
DO - 10.4097/kjae.2012.63.5.425
M3 - Article
C2 - 23198036
AN - SCOPUS:84870489638
SN - 2005-6419
VL - 63
SP - 425
EP - 430
JO - Korean Journal of Anesthesiology
JF - Korean Journal of Anesthesiology
IS - 5
ER -