Abstract
Background/Aims: Recently, several studies have revealed that diagnostic imaging can result in exposure to harmful levels of ionizing radiation in inflammatory bowel disease pa tients. However, the extent of radiation exposure in intestinal Behçet disease (BD) patients has not been documented. The aim of this study was to estimate the radiation exposure from abdominal imaging studies in intestinal BD patients. Meth ods: Patients with a diagnosis of intestinal BD established between January 1990 and March 2012 were investigated at a single tertiary academic medical center. The cumula tive effective dose (CED) was calculated retrospectively from standard tables and by counting the number of abdominal imaging studies performed. High exposure was defined as CED >50 mSv. Results: In total, 270 patients were included in the study. The mean CED was 41.3 mSv, and 28.1% of patients were exposed to high levels of radiation. Computed tomography (CT) accounted for 81.7% of the total effective dose. In multivariate analyses, predictors of high radiation exposure were azathioprine/6-mercaptopurine use, surgery, and hospitalization. Conclusions: Approximately a quarter of intestinal BD patients were exposed to harmful levels of diagnostic radiation, mainly from CT examination. Clinicians should reduce the number of unnecessary CT examinations and consider low-dose CT profiles or alternative modali ties such as magnetic resonance enterography.
Original language | English |
---|---|
Pages (from-to) | 380-387 |
Number of pages | 8 |
Journal | Gut and Liver |
Volume | 8 |
Issue number | 4 |
DOIs | |
State | Published - Jul 2014 |
Keywords
- Clinical course
- Intestinal Behcet disease
- Prog nostic factors
- Radiation