Skip to main navigation Skip to search Skip to main content

Quality assurance incorporating artificial intelligence-generated reference contours in a phase II radiotherapy trial

  • Wonhyeong Lee
  • , Yeon Joo Kim
  • , Jin Hee Kim
  • , Sung Ja Ahn
  • , Jong Hoon Lee
  • , Younghee Park
  • , Jin Hwa Choi
  • , Jin ho Song
  • , Yoonsun Chung

Research output: Contribution to journal › Article › peer-review

Abstract

Background and purposeA dummy run quality assurance was conducted for a prospective phase II trial of tailored radiotherapy (RT) according to the response after neoadjuvant chemotherapy (NAC) followed by surgery in locally advanced breast cancer (RTaNAC). Since inter-institutional variations in dose distributions can impact clinical outcomes, this dummy run aimed to develop an RT plan protocol to minimize these variations.Material and methodsThis study involved computed tomography images from three clinical scenarios: RT with no lymph node (LN) boost (Scenario 1), LN boost up to 60 Gy3.5, equivalent dose in 2 Gy fractions (EQD2) with α/β = 3.5 Gy (Scenario 2), and LN boost up to 66 Gy3.5 (Scenario 3). Seven institutions developed RT plans under a two-step process: first according to each institution’s policies (Step 1) and then using additional reference information, including artificial intelligence (AI) auto-contoured structures and LN boost target volume information (Step 2). Dose-volume histograms for breast and regional nodal areas were analyzed between the two steps.ResultsInter-institutional variation observed in Step 1 improved in Step 2 for breast and regional nodal areas. Specifically for Scenario 1, dose coverage for the nodal clinical target volumes of the axillary level I LN improved from 57.5% to 97.5% (p-value = 0.075), and that of the supraclavicular LN improved from 75.6% to 88.8% (p-value = 0.046).ConclusionVariations in dose/volume metrics among institutions were mitigated by AI auto-contoured structures and LN boost target volume information. Through this dummy run, the participating institutions reached a consensus on an RT plan protocol to support multi-institutional expansion of RTaNAC.

Original languageEnglish
Article number100949
JournalPhysics and Imaging in Radiation Oncology
Volume38
DOIs
StatePublished - Mar 2026

Bibliographical note

Publisher Copyright:
© 2026 The Authors. Published by Elsevier B.V. on behalf of European Society of Radiotherapy & Oncology. This is an open access article under the CC BY license. http://creativecommons.org/licenses/by/4.0/

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Breast cancer
  • Dummy run
  • Multi-institutional study
  • Neoadjuvant chemotherapy
  • Regional nodal irradiation

Fingerprint

Dive into the research topics of 'Quality assurance incorporating artificial intelligence-generated reference contours in a phase II radiotherapy trial'. Together they form a unique fingerprint.

Cite this