Prevalidation trial for a novel in vitro eye irritation test using the reconstructed human cornea-like epithelial model, MCTT HCE™

Hyeri Yang, Da eun Kim, Won Hee Jang, Susun An, Sun A. Cho, Mi Sook Jung, Ji Eun Lee, Kyung Wook Yeo, Sang Bum Koh, Tae Cheon Jeong, Mi Jeong Kang, Young Jin Chun, Su Hyon Lee, Kyung Min Lim, Seung Jin Bae

Research output: Contribution to journalArticlepeer-review

16 Scopus citations

Abstract

Here, we report the results of a prevalidation trial for an in vitro eye irritation test (EIT) using the reconstructed human cornea-like epithelium, MCTT HCE™. The optimal cutoff to determine irritation in the prediction model was established at 35% with the receiver operation characteristics(ROC) curve for 126 substances. Within-lab(WL) and between-lab(BL) reproducibility was tested for 20 reference substances by 3 participating laboratories. Viability data described by mean ± SD or ± 1/2 difference between duplicate wells, and scatter plots, demonstrated the WL/BL consistency. WL/BL concordance with the binary decision, whether non-irritant or irritant was estimated to be 85–95% and 95%, respectively. WL/BL reproducibility of viability data was further supported by a strong correlation(ICC, r > 0.9). WL/BL agreement of binary decisions was also examined by Fleiss' Kappa statistics, which showed a strong level of agreement (> 0.78), nevertheless weaker than the reproducibility of the viability. The EIT with MCTT HCE™ exhibited a sensitivity of 82.2% (60/73), a specificity of 81.1% (43/53), and an accuracy of 81.8% (103/126) for 126 reference substances (for liquids; a sensitivity of 100% (47/47), a specificity of 70.6% (24/34), and an accuracy of 87.7% (71/81), and for solids, a sensitivity of 50% (13/26), a specificity of 100% (19/19), and an accuracy of 71.1% (32/45), suggesting that the accuracy is satisfactory but the sensitivity needs improvement, which shall be addressed through correcting the poor sensitivity for solid substances in future full validation trials.

Original languageEnglish
Pages (from-to)58-67
Number of pages10
JournalToxicology in Vitro
Volume39
DOIs
StatePublished - 1 Mar 2017

Bibliographical note

Publisher Copyright:
© 2016 Elsevier Ltd

Keywords

  • Eye irritation test
  • MCTT HCE™
  • Predictive capacity
  • Reproducibility
  • Statistical analysis

Fingerprint

Dive into the research topics of 'Prevalidation trial for a novel in vitro eye irritation test using the reconstructed human cornea-like epithelial model, MCTT HCE™'. Together they form a unique fingerprint.

Cite this