Abstract
Results from an experimental program on the behaviour of high strength concrete-filled steel hollow structural section (HSS) columns will he presented for three types of concrete filling. A comparison will he made of the fire-resistance performance of HSS columns filled with normal strength concrete, high strength concrete, and steel-fibre-reinforced high strength concrete. The various factors that influence the structural behaviour of high strength concrete-filled HSS columns under fire conditions are discussed. It is demonstrated that, in many cases, addition of steel fibres into high strength concrete improves the fire resistance and offers an economical solution for fire-safe construction.
Original language | English |
---|---|
Pages (from-to) | 975-981 |
Number of pages | 7 |
Journal | Canadian Journal of Civil Engineering |
Volume | 25 |
Issue number | 6 |
DOIs | |
State | Published - 1998 |
Keywords
- Concrete-filled steel columns
- Fire-resistance design
- High strength concrete
- High-temperature behaviour
- Steel columns