Skip to main navigation Skip to search Skip to main content

Masseter Muscle Volume and Cross-Sectional Area as Risk Factors for Late Mechanical Dental Implant Failure: A Matched Case–Control Study

Research output: Contribution to journal › Article › peer-review

Abstract

Objectives: This study aimed to investigate whether three-dimensional (3D) masseter muscle morphology—volume and cross-sectional area (CSA)—is associated with the risk of late mechanical dental implant failure and to derive preliminary cut-off values for risk stratification. Material and Methods: This 1:4 matched case–control study investigated 23 cases of late mechanical failure (fixture fracture, screw fracture, or abutment fracture) and 92 successful controls. Participants were matched by gender, age (±10 years), anatomical location, and maintenance period (±2 years). Masseter morphology was quantified using the 3D reconstruction of the cone-beam computed tomography (CBCT) data. Independent risk factors were determined using a multivariable generalized estimating equation model adjusting for potential confounders. Results: Increased masseter muscle bulk was significantly associated with mechanical failure (p < 0.001). The odds of mechanical failure increased by 1.24-fold per 1000 mm3 increase in masseter volume and by 1.11-fold per 10 mm2 increase in CSA. ROC analysis demonstrated AUCs of 0.846 for masseter volume and 0.871 for CSA. The maximum-Youden thresholds were 31,272.56 mm3 for volume and 691.30 mm2 for CSA, with sensitivities of 86.96% and 82.61% and specificities of 77.17% and 79.35%, respectively. Internal bootstrap validation yielded AUC 95% confidence intervals of 0.751–0.931 and 0.767–0.951, respectively. Conclusions: Greater masseter muscle volume and CSA were significantly associated with late mechanical implant failure in this matched case–control study. The proposed cut-off values may provide preliminary reference values for risk stratification. However, these findings should be regarded as exploratory and require prospective validation in independent cohorts before routine clinical implementation.

Original languageEnglish
JournalClinical Oral Implants Research
DOIs
StateAccepted/In press - 2026

Bibliographical note

Publisher Copyright:
© 2026 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Keywords

  • cone-beam computed tomography
  • dental implants
  • dental restoration failure
  • masseter muscle
  • risk factors

Fingerprint

Dive into the research topics of 'Masseter Muscle Volume and Cross-Sectional Area as Risk Factors for Late Mechanical Dental Implant Failure: A Matched Case–Control Study'. Together they form a unique fingerprint.

Cite this