T1 - Evaluation of the efficacies of rapid antigen test, multiplex PCR, and real-time PCR for the detection of a novel influenza a (H1N1) virus
AU - Hwang, Yusun
AU - Kim, Kyounghee
AU - Lee, Miae
PY - 2010
Y1 - 2010
N2 - Background: In April 2009, a novel influenza A (H1N1) virus was detected in the US, and at the time of conducting this study, H1N1 infection had reached pandemic proportions. In Korea, rapid antigen tests and PCR assays have been developed to detect the H1N1 virus. We evaluated the efficacies of rapid antigen test, multiplex PCR, and real-time PCR for detecting the H1N1 virus. Methods: From August to September 2009, we tested 734 samples obtained from nasopharyngeal swab or nasal swab using rapid antigen test (SD Influenza Antigen, Standard Diagnostics, Inc., Korea) and multiplex PCR (Seeplex FluA ACE Subtyping, Seegene, Korea). We also tested 224 samples using the AdvanSure real-time PCR (LG Life Sciences, Korea) to compare the results obtained using real-time PCR with those obtained using multiplex PCR. Furthermore, 99 samples were tested using the AdvanSure real-time PCR and the AccuPower real-time PCR (Bioneer, Korea). Results: In comparison with the results of multiplex PCR, the sensitivity and specificity of the rapid antigen test were 48.0% and 99.8%, respectively. The concordance rate for multiplex PCR and the AdvanSure real-time PCR was 99.6% (k=0.991, P=0.000), and that for the AdvanSure real-time PCR and the AccuPower real-time PCR was 97.0% (k=0.936, P=0.000). Conclusions: The rapid antigen test is significantly less sensitive than PCR assay; therefore, it is not useful for H1N1 detection; however multiplex PCR, the AdvanSure real-time PCR, and the Accu-Power real-time PCR can be useful for H1N1 detection.
AB - Background: In April 2009, a novel influenza A (H1N1) virus was detected in the US, and at the time of conducting this study, H1N1 infection had reached pandemic proportions. In Korea, rapid antigen tests and PCR assays have been developed to detect the H1N1 virus. We evaluated the efficacies of rapid antigen test, multiplex PCR, and real-time PCR for detecting the H1N1 virus. Methods: From August to September 2009, we tested 734 samples obtained from nasopharyngeal swab or nasal swab using rapid antigen test (SD Influenza Antigen, Standard Diagnostics, Inc., Korea) and multiplex PCR (Seeplex FluA ACE Subtyping, Seegene, Korea). We also tested 224 samples using the AdvanSure real-time PCR (LG Life Sciences, Korea) to compare the results obtained using real-time PCR with those obtained using multiplex PCR. Furthermore, 99 samples were tested using the AdvanSure real-time PCR and the AccuPower real-time PCR (Bioneer, Korea). Results: In comparison with the results of multiplex PCR, the sensitivity and specificity of the rapid antigen test were 48.0% and 99.8%, respectively. The concordance rate for multiplex PCR and the AdvanSure real-time PCR was 99.6% (k=0.991, P=0.000), and that for the AdvanSure real-time PCR and the AccuPower real-time PCR was 97.0% (k=0.936, P=0.000). Conclusions: The rapid antigen test is significantly less sensitive than PCR assay; therefore, it is not useful for H1N1 detection; however multiplex PCR, the AdvanSure real-time PCR, and the Accu-Power real-time PCR can be useful for H1N1 detection.
KW - Multiplex PCR
KW - Novel influenza A (H1N1) virus
KW - Rapid antigen test
KW - Real-time PCR
UR - http://www.scopus.com/inward/record.url?scp=77954838579&partnerID=8YFLogxK
U2 - 10.3343/kjlm.2010.30.2.147
DO - 10.3343/kjlm.2010.30.2.147
M3 - Article
C2 - 20445332
AN - SCOPUS:77954838579
SN - 1598-6535
VL - 30
SP - 147
EP - 152
JO - Korean Journal of Laboratory Medicine
JF - Korean Journal of Laboratory Medicine
IS - 2
ER -