Evaluating the calibration of MTSAT-1R infrared channels using collocated Terra MODIS measurements

Byung Ju Sohn, Hye Sook Park, Hyo Jin Han, Myoung Hwan Ahn

Research output: Contribution to journalArticlepeer-review

15 Scopus citations

Abstract

The calibration of four MTSAT-1R infrared channels was evaluated by comparing MTSAT measurements with Terra/MODIS inferred MTSAT-equivalent brightness temperatures during August 2005 and August 2006. Theoretical relationships converting MODIS brightness temperatures to MTSAT-equivalent values were obtained and used for the comparison. Results indicate that MTSAT two split window channels are well calibrated, and no serious systematic errors or biases are found; and the MTSAT water-vapour channel shows a good linear relationship but with a warm bias up to 2 K. The significant cold bias of MTSAT 3.7 μm channel about -6.7 K in August 2005 is found to be much removed in August 2006, after correction of the electrical crosstalk between MTSAT-1R SWIR channel and WV channel starting from March 2006. Since then, calibration performances of MTSAT-1R split window channels and shortwave IR channel seem to be comparable with MODIS calibration, while the water-vapour channel shows more uncertainties up to 2 K of bias.

Original languageEnglish
Pages (from-to)3033-3042
Number of pages10
JournalInternational Journal of Remote Sensing
Volume29
Issue number10
DOIs
StatePublished - May 2008

Bibliographical note

Funding Information:
This research has been supported by the Korean Geostationary Satellite Program (COMS) funded through the Korean Meteorological Administration (KMA).

Fingerprint

Dive into the research topics of 'Evaluating the calibration of MTSAT-1R infrared channels using collocated Terra MODIS measurements'. Together they form a unique fingerprint.

Cite this