TY - JOUR
T1 - Dual-energy CT in the assessment of mediastinal lymph nodes
T2 - Comparative study of virtual non-contrast and true non-contrast images
AU - Yoo, Seon Young
AU - Kim, Yookyung
AU - Cho, Hyun Hae
AU - Choi, Mi Joo
AU - Shim, Sung Shine
AU - Lee, Jeong Kyong
AU - Baek, Seung Yon
PY - 2013/5
Y1 - 2013/5
N2 - Objective: To evaluate the reliability of virtual non-contrast (VNC) images reconstructed from contrast-enhanced, dual-energy scans compared with true non-contrast (TNC) images in the assessment of high CT attenuation or calcification of mediastinal lymph nodes. Materials and Methods: A total of 112 mediastinal nodes from 45 patients who underwent non-contrast and dual-energy contrast-enhanced scans were analyzed. Node attenuation in TNC and VNC images was compared both objectively, using computed tomography (CT) attenuation, and subjectively, via visual scoring (0, attenuation ≤ the aorta; 1, > the aorta; 2, calcification). The relationship among attenuation difference between TNC and VNC images, CT attenuation in TNC images, and net contrast enhancement (NCE) was analyzed. Results: CT attenuation in TNC and VNC images showed moderate agreement (intraclass correlation coefficient, 0. 612). The mean absolute difference was 7. 8 ± 7. 6 Hounsfield unit (HU) (range, 0-36 HU), and the absolute difference was equal to or less than 10 HU in 65. 2% of cases (73/112). Visual scores in TNC and VNC images showed fair agreement (k value, 0. 335). Five of 16 nodes (31. 3%) which showed score 1 (n = 15) or 2 (n = 1) in TNC images demonstrated score 1 in VNC images. The TNC-VNC attenuation difference showed a moderate positive correlation with CT attenuation in TNC images (partial correlation coefficient [PCC] adjusted by NCE: 0. 455) and a weak negative correlation with NCE (PCC adjusted by CT attenuation in TNC: -0. 245). Conclusion: VNC images may be useful in the evaluation of mediastinal lymph nodes by providing additional information of high CT attenuation of nodes, although it is underestimated compared with TNC images.
AB - Objective: To evaluate the reliability of virtual non-contrast (VNC) images reconstructed from contrast-enhanced, dual-energy scans compared with true non-contrast (TNC) images in the assessment of high CT attenuation or calcification of mediastinal lymph nodes. Materials and Methods: A total of 112 mediastinal nodes from 45 patients who underwent non-contrast and dual-energy contrast-enhanced scans were analyzed. Node attenuation in TNC and VNC images was compared both objectively, using computed tomography (CT) attenuation, and subjectively, via visual scoring (0, attenuation ≤ the aorta; 1, > the aorta; 2, calcification). The relationship among attenuation difference between TNC and VNC images, CT attenuation in TNC images, and net contrast enhancement (NCE) was analyzed. Results: CT attenuation in TNC and VNC images showed moderate agreement (intraclass correlation coefficient, 0. 612). The mean absolute difference was 7. 8 ± 7. 6 Hounsfield unit (HU) (range, 0-36 HU), and the absolute difference was equal to or less than 10 HU in 65. 2% of cases (73/112). Visual scores in TNC and VNC images showed fair agreement (k value, 0. 335). Five of 16 nodes (31. 3%) which showed score 1 (n = 15) or 2 (n = 1) in TNC images demonstrated score 1 in VNC images. The TNC-VNC attenuation difference showed a moderate positive correlation with CT attenuation in TNC images (partial correlation coefficient [PCC] adjusted by NCE: 0. 455) and a weak negative correlation with NCE (PCC adjusted by CT attenuation in TNC: -0. 245). Conclusion: VNC images may be useful in the evaluation of mediastinal lymph nodes by providing additional information of high CT attenuation of nodes, although it is underestimated compared with TNC images.
KW - Chest
KW - Dual-energy CT
KW - Iodine subtraction
KW - Lymph nodes
KW - Virtual non-contrast
UR - http://www.scopus.com/inward/record.url?scp=84877985395&partnerID=8YFLogxK
U2 - 10.3348/kjr.2013.14.3.532
DO - 10.3348/kjr.2013.14.3.532
M3 - Article
C2 - 23690725
AN - SCOPUS:84877985395
SN - 1229-6929
VL - 14
SP - 532
EP - 539
JO - Korean Journal of Radiology
JF - Korean Journal of Radiology
IS - 3
ER -