N2 - Objectives: The aim of this systematic review and meta-analysis was to assess the sensitivity and specificity of dual-energy CT (DECT) for the detection of bone marrow oedema (BME). Methods: An electronic search of the PubMed and EMBASE databases was conducted. Bivariate modelling and hierarchical summary receiver-operating characteristic modelling were performed to evaluate the overall diagnostic performance of DECT for BME. Subgroup analysis was performed according to the assessment type (qualitative vs. quantitative) and anatomical location (spine vs. appendicular skeleton). Meta-regression analyses were performed according to the subject, study, and DECT characteristics. Results: Twelve eligible studies (1901 lesions, 450 patients) were included. DECT exhibited a pooled sensitivity of 0.85 [95% confidence interval (CI): 0.78–0.90] and a pooled specificity of 0.97 (95% CI: 0.92–0.98) for BME detection. In addition, the diagnostic performance of qualitative assessment (sensitivity, 0.85; specificity, 0.97) was higher than that of quantitative assessment (sensitivity, 0.84; specificity, 0.88) of DECT findings. The diagnostic performance of DECT for the spine (sensitivity, 0.84; specificity, 0.98) and appendicular skeleton (sensitivity, 0.84; specificity, 0.93) were excellent. According to meta-regression analysis, the use of a tin filter, ≥ 2 image planes, and a slice thickness < 1 mm tended to exhibit higher sensitivity and hyperacute stage BME (< 24 h) tended to exhibit lower sensitivity. Conclusions: These findings indicate that DECT has excellent sensitivity and specificity for BME detection. Qualitative assessment of DECT findings obtained using a tin filter, ≥ 2 image planes, and a 0.5-1-mm slice thickness in the acute stage BME (≥24 h) is recommended for more sensitive diagnosis. Key Points: • Overall, DECT is useful for the detection of BME (sensitivity, 85%; specificity-97%). • Qualitative assessment (sensitivity-85%; specificity-97%) is more accurate than quantitative assessment (sensitivity-84%; specificity-88%). • DECT showed excellent diagnostic performance for both the spine/appendicular skeleton (sensitivity-84%/84%; specificity-98%/93%).
AB - Objectives: The aim of this systematic review and meta-analysis was to assess the sensitivity and specificity of dual-energy CT (DECT) for the detection of bone marrow oedema (BME). Methods: An electronic search of the PubMed and EMBASE databases was conducted. Bivariate modelling and hierarchical summary receiver-operating characteristic modelling were performed to evaluate the overall diagnostic performance of DECT for BME. Subgroup analysis was performed according to the assessment type (qualitative vs. quantitative) and anatomical location (spine vs. appendicular skeleton). Meta-regression analyses were performed according to the subject, study, and DECT characteristics. Results: Twelve eligible studies (1901 lesions, 450 patients) were included. DECT exhibited a pooled sensitivity of 0.85 [95% confidence interval (CI): 0.78–0.90] and a pooled specificity of 0.97 (95% CI: 0.92–0.98) for BME detection. In addition, the diagnostic performance of qualitative assessment (sensitivity, 0.85; specificity, 0.97) was higher than that of quantitative assessment (sensitivity, 0.84; specificity, 0.88) of DECT findings. The diagnostic performance of DECT for the spine (sensitivity, 0.84; specificity, 0.98) and appendicular skeleton (sensitivity, 0.84; specificity, 0.93) were excellent. According to meta-regression analysis, the use of a tin filter, ≥ 2 image planes, and a slice thickness < 1 mm tended to exhibit higher sensitivity and hyperacute stage BME (< 24 h) tended to exhibit lower sensitivity. Conclusions: These findings indicate that DECT has excellent sensitivity and specificity for BME detection. Qualitative assessment of DECT findings obtained using a tin filter, ≥ 2 image planes, and a 0.5-1-mm slice thickness in the acute stage BME (≥24 h) is recommended for more sensitive diagnosis. Key Points: • Overall, DECT is useful for the detection of BME (sensitivity, 85%; specificity-97%). • Qualitative assessment (sensitivity-85%; specificity-97%) is more accurate than quantitative assessment (sensitivity-84%; specificity-88%). • DECT showed excellent diagnostic performance for both the spine/appendicular skeleton (sensitivity-84%/84%; specificity-98%/93%).
KW - Bone marrow
KW - Dual-energy scanned projection radiography
KW - Meta-analysis
KW - Multidetector computed tomography
KW - Sensitivity
UR - http://www.scopus.com/inward/record.url?scp=85045745727&partnerID=8YFLogxK
U2 - 10.1007/s00330-018-5411-5
DO - 10.1007/s00330-018-5411-5
M3 - Article
C2 - 29679212
AN - SCOPUS:85045745727
SN - 0938-7994
VL - 28
SP - 4182
EP - 4194
JO - European Radiology
JF - European Radiology
IS - 10
ER -