TY - JOUR
T1 - Comparison of experience curves between two 3-dimensional intraoral scanners
AU - Kim, Jisun
AU - Park, Ji Man
AU - Kim, Minji
AU - Heo, Seong Joo
AU - Shin, Im Hee
AU - Kim, Miae
N1 - Publisher Copyright:
© 2016 Editorial Council for the Journal of Prosthetic Dentistry
PY - 2016/8/1
Y1 - 2016/8/1
N2 - Statement of problem Conventional impression-making methods are being replaced by intraoral digital scanning. How long dental professionals take to master the new technologies is unknown. Purpose The purpose of this human subject study was to compare the experience curves of 2 intraoral scanners among dental hygienists and determine whether repeated scanning experience could change the scan time (ST). Material and methods A total of 29 dental hygienists with more than 3 years of working experience were recruited (group 1: 3-5 years; group 2: >6 years of clinical experience) to learn the iTero and Trios systems. All learners scanned the oral cavities of 4 human participants (participants A, B, C, and D) 10 times (T1-T10) throughout the learning sessions and the experimental dentoform model twice at the beginning and end of the 10 sessions. ST was measured, and changes in ST were compared between the 2 devices. Results The average ST for 10 sessions was greater with iTero than with Trios, but the decrease in the measured ST was greater for iTero than for Trios. Baseline and postexperience STs with iTero showed statistically significant differences, with a decrease in time related to the clinical experience levels of the dental hygienists (group 1: T2 and T4, P<.01; group 2: T2 and T5, P<.01). The experience curve with iTero was not influenced by the human participant's intraoral characteristics, and greater ST was shown for participants B and C than for participants A and D with Trios. Conclusions Although the learning rate of iTero was rapid, the average ST for iTero was longer than Trios, and clinical experience levels influenced the operator's ability to manipulate the device. In contrast, the learning rate of Trios was slow, and measured ST was shorter than iTero, and was not influenced by clinical experience.
AB - Statement of problem Conventional impression-making methods are being replaced by intraoral digital scanning. How long dental professionals take to master the new technologies is unknown. Purpose The purpose of this human subject study was to compare the experience curves of 2 intraoral scanners among dental hygienists and determine whether repeated scanning experience could change the scan time (ST). Material and methods A total of 29 dental hygienists with more than 3 years of working experience were recruited (group 1: 3-5 years; group 2: >6 years of clinical experience) to learn the iTero and Trios systems. All learners scanned the oral cavities of 4 human participants (participants A, B, C, and D) 10 times (T1-T10) throughout the learning sessions and the experimental dentoform model twice at the beginning and end of the 10 sessions. ST was measured, and changes in ST were compared between the 2 devices. Results The average ST for 10 sessions was greater with iTero than with Trios, but the decrease in the measured ST was greater for iTero than for Trios. Baseline and postexperience STs with iTero showed statistically significant differences, with a decrease in time related to the clinical experience levels of the dental hygienists (group 1: T2 and T4, P<.01; group 2: T2 and T5, P<.01). The experience curve with iTero was not influenced by the human participant's intraoral characteristics, and greater ST was shown for participants B and C than for participants A and D with Trios. Conclusions Although the learning rate of iTero was rapid, the average ST for iTero was longer than Trios, and clinical experience levels influenced the operator's ability to manipulate the device. In contrast, the learning rate of Trios was slow, and measured ST was shorter than iTero, and was not influenced by clinical experience.
UR - http://www.scopus.com/inward/record.url?scp=84962745918&partnerID=8YFLogxK
U2 - 10.1016/j.prosdent.2015.12.018
DO - 10.1016/j.prosdent.2015.12.018
M3 - Article
C2 - 27061634
AN - SCOPUS:84962745918
SN - 0022-3913
VL - 116
SP - 221
EP - 230
JO - Journal of Prosthetic Dentistry
JF - Journal of Prosthetic Dentistry
IS - 2
ER -