Comparing the safety and effectiveness of overlapping stents with flow diverters for unruptured vertebral artery dissecting aneurysms

Hyung Jun Kim, Na Rae Yang, Tae Keun Jee, Je Young Yeon, Keon Ha Kim, Jong Soo Kim, Woo Keun Seo, Pyoung Jeon

Research output: Contribution to journalArticlepeer-review

3 Scopus citations

Abstract

Background Endovascular treatment for vertebral artery dissecting aneurysms (VADAs) includes overlapping stents and flow diverters. This study compared the safety and effectiveness of overlapping stents and flow diverters for unruptured VADAs. Methods We retrospectively enrolled patients with unruptured VADAs who underwent overlapping stents or flow diverters at two tertiary hospitals in South Korea. The primary clinical outcome was the occurrence of stroke. The primary angiographic outcomes (>12 months) were categorized as regression, no decrease in size, recanalization, or stent occlusion, of which only regression was defined as a favorable angiographic outcomes. Results Of the 146 patients with VADAs, 25 (17.1%) had flow diverters and 121 (82.9%) had overlapping stents. For the primary angiographic outcomes over 12 months, the rate of favorable angiographic outcomes for flow diverters was 81.8% and for overlapping stents (triple stents) was 98.8% (P=0.006). In the multivariale analysis, after adjusting for partially thrombosed aneurysms, aneurysm shape, non-dominant vessel, posterior inferior cerebellar artery involvement, and procedure type, overlapping stents (triple stents) was not associated with favorable angiographic outcomes compared with flow diverters (OR 7.040, 95% CI 0.549 to 90.294; P=0.134), but partially thrombosed aneurysms was inversely associated with favorable angiographic outcomes (OR 0.056, 95% CI 0.005 to 0.589; P=0.016). The primary clinical outcome followed up to the last angiography did not occur in all patients. Conclusion There was no difference in safety and effectiveness between overlapping stents and flow diverters in unruptured VADAs. Further endovascular treatment studies are needed regarding the association of partially thrombosed aneurysms with unfavorable angiographic outcomes.

Original languageEnglish
Pages (from-to)725-730
Number of pages6
JournalJournal of NeuroInterventional Surgery
Volume17
Issue number7
DOIs
StatePublished - 1 Jul 2025

Bibliographical note

Publisher Copyright:
© Author(s) (or their employer(s)) 2025. No commercial re-use. See rights and permissions. Published by BMJ Group.

Keywords

  • Aneurysm
  • Dissection
  • Flow Diverter
  • Stent