Automated quantification of mitral regurgitation by three dimensional real time full volume color doppler transthoracic echocardiography: A validation with cardiac magnetic resonance imaging and comparison with two dimensional quantitative methods

Jang Won Son, Hyuk Jae Chang, Jin Kyung Lee, Hee Jung Chung, Ran Young Song, Young Jin Kim, Saurabh Datta, Ran Heo, Sang Hoon Shin, In Jeong Cho, Chi Young Shim, Geu Ru Hong, Namsik Chung

Research output: Contribution to journalArticlepeer-review

23 Scopus citations

Abstract

Background: Accurate assessment of mitral regurgitation (MR) severity is crucial for clinical decision-making and optimizing patient outcomes. Recent advances in real-time three dimensional (3D) echocardiography provide the option of real-time full volume color Doppler echocardiography (FVCD) measurements. This makes it practical to quantify MR by subtracting aortic stroke volume from the volume of mitral inflow in an automated manner. Methods: Thirty-two patients with more than a moderate degree of MR assessed by transthoracic echocardiography (TTE) were consecutively enrolled during this study. MR volume was measured by 1) two dimensional (2D) Doppler TTE, using the proximal isovelocity surface area (PISA) and the volumetric quantification methods (VM). Then, 2) real time 3D-FVCD was subsequently obtained, and dedicated software was used to quantify the MR volume. MR volume was also measured using 3) phase contrast cardiac magnetic resonance imaging (PC-CMR). In each patient, all these measurements were obtained within the same day. Automated MR quantification was feasible in 30 of 32 patients. Results: The mean regurgitant volume quantified by 2D-PISA, 2D-VM, 3D-FVCD, and PC-CMR was 72.1 ± 27.7, 79.9 ± 36.9, 69.9 ± 31.5, and 64.2 ± 30.7 mL, respectively (p = 0.304). There was an excellent correlation between the MR volume measured by PC-CMR and 3D-FVCD (r = 0.85, 95% CI 0.70-0.93, p < 0.001). Compared with PC-CMR, Bland-Altman analysis for 3D-FVCD showed a good agreement (2 standard deviations: 34.3 mL) than did 2D-PISA or 2D-VM (60.0 and 62.8 mL, respectively). Conclusion: Automated quantification of MR with 3D-FVCD is feasible and accurate. It is a promising tool for the real-time 3D echocardiographic assessment of patients with MR.

Original languageEnglish
Pages (from-to)81-89
Number of pages9
JournalJournal of Cardiovascular Ultrasound
Volume21
Issue number2
DOIs
StatePublished - 2013

Keywords

  • 3D echocardiography
  • Mitral regurgitation
  • Quantitative evaluation

Fingerprint

Dive into the research topics of 'Automated quantification of mitral regurgitation by three dimensional real time full volume color doppler transthoracic echocardiography: A validation with cardiac magnetic resonance imaging and comparison with two dimensional quantitative methods'. Together they form a unique fingerprint.