Abstract
This article describes an arthroscopic technique for the fixation of clavicle shaft fractures. A viewing portal is made 2 cm anterior to the fracture site, and a working portal is made 2 cm lateral to the fracture site. The guide wire for a 4.0-mm cannulated screw is inserted through the fracture site to the medial fracture fragment under arthroscopic guidance. Through the medial fragment, the guide wire is delivered through the skin anteriorly. The fracture is reduced, and then, the guide wire is drilled back across the fracture site to the lateral fracture fragment. After confirming the reduction under arthroscopy, the appropriately sized cannulated screw is inserted after reaming. This arthroscopic technique would be useful for the precise reduction and minimal invasive fixation of clavicle shaft fractures. Preliminary results are encouraging, and further studies with long-term follow-up are needed to determine the precise indications and limitations of the procedure.
Original language | English |
---|---|
Journal | Journal of Orthopaedic Surgery |
Volume | 25 |
Issue number | 1 |
DOIs | |
State | Published - 1 Jan 2017 |
Bibliographical note
Publisher Copyright:© Journal of Orthopaedic Surgery 2017.
Keywords
- Arthroscopy
- Cannulated screw
- Clavicle fracture
- Minimal invasive
- Viewing portal
- Working portal