Analysis of vertical and horizontal circular C-arm trajectories

A. Maier, J. H. Choi, A. Keil, C. Niebler, M. Sarmiento, A. Fieselmann, G. Gold, S. Delp, R. Fahrig

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

26 Scopus citations

Abstract

C-arm angiography systems offer great flexibility in the acquisition of trajectories for computed tomography. Theoretically, these systems are able to scan patients while standing in an upright position. This would allow novel insights into structural changes of the human anatomy while weight bearing. However, this would require a scan on a horizontal trajectory parallel to the ground floor which is currently not supported by standard C-arm CT acquisition protocols. In this paper, we compared the standard vertical and the new horizontal scanning trajectories by analysis of the source positions and source to detector distances during the scan. We employed a C-arm calibration phantom to compute the exact scan geometry. Based on the analysis of the projection matrices, we computed the source position in 3D and the source to detector distance for each projection. We then used the calibrated scan geometries to reconstruct the calibration phantom. Based on this reconstruction in comparison to the ideal phantom geometry we also evaluated the geometric reconstruction error. As expected, both the vertical and the horizontal scan trajectories exhibit a significant C-arm "wobble". But in both kinds of trajectories, the reproducibility over several scans was comparable. We were able to reconstruct the calibration phantom with satisfactory geometric reconstruction accuracy. With a reconstruction error of 0.2 mm, we conclude that horizontal C-arm scans are possible and show properties similar to those of vertical C-arm scans. The remaining challenge is compensation for the involuntary movement of the standing subject during a weight-bearing acquisition. We investigated this using an optical tracking system and found that the average movement at the knee while standing upright for 5 seconds is between 0.42 mm and 0.54 mm, and goes up to as much as 12 mm when the subject is holding a 60° squat. This involuntary motion is much larger than the reconstruction accuracy. Hence, we expect artifacts in reconstructions to be significant for upright positions, and overwhelming in squat positions if no motion correction is applied.

Original languageEnglish
Title of host publicationMedical Imaging 2011
Subtitle of host publicationPhysics of Medical Imaging
DOIs
StatePublished - 2011
EventMedical Imaging 2011: Physics of Medical Imaging - Lake Buena Vista, FL, United States
Duration: 13 Feb 201117 Feb 2011

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume7961
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2011: Physics of Medical Imaging
Country/TerritoryUnited States
CityLake Buena Vista, FL
Period13/02/1117/02/11

Fingerprint

Dive into the research topics of 'Analysis of vertical and horizontal circular C-arm trajectories'. Together they form a unique fingerprint.

Cite this