Alumina Delta-on-Highly Crosslinked-Remelted Polyethylene Bearing in Cementless Total Hip Arthroplasty in Patients Younger than 50 Years

Young Hoo Kim, Jang Won Park, Jun Shik Kim

Research output: Contribution to journalArticlepeer-review

14 Scopus citations

Abstract

Background The purpose of this retrospective study was to determine the clinical and radiographic results, prevalence of polyethylene wear and osteolysis, and fracture of alumina delta ceramic femoral head or highly crosslinked, remelted polyethylene (HXLPE) liner associated with the use of alumina delta ceramic femoral head-on-HXLPE bearing in cementless total hip arthroplasty in patients younger than 50 years. Methods We reviewed the cases of 119 patients (130 hips) who underwent a cementless total hip arthroplasty using alumina delta ceramic-on-HXLPE bearing when they were 50 years or younger at the time of surgery. The most common diagnoses were osteonecrosis (51%) and osteoarthritis secondary to developmental dysplastic hip (39%). Osteolysis and polyethylene wear rates were evaluated with use of radiography and computed tomography. In addition, prevalence of fracture of alumina delta ceramic head and polyethylene line was documented. The mean follow-up was 8.3 years (range, 7-9 years). Results The mean Harris hip score, Western Ontario and McMaster Universities Osteoarthritis Index score, University of California, Los Angeles activity score were 94 points, 14 points, and 8.1 points, respectively, at the final follow-up. No patient had thigh pain. All acetabular components and all but one femoral components were well fixed. The mean annual penetration rate of femoral head was 0.022 ± 0.003 mm/year. No hip had osteolysis or ceramic head or HXLPE liner fracture. Conclusion Our average 8.3-year results with the use of alumina delta ceramic-on-HXLPE bearing in the patients younger than 50 years suggest that cementless acetabular and femoral components provide a high survival rate without evidence of osteolysis or ceramic head or AXLPE liner fracture.

Original languageEnglish
Pages (from-to)2800-2804
Number of pages5
JournalJournal of Arthroplasty
Volume31
Issue number12
DOIs
StatePublished - 1 Dec 2016

Bibliographical note

Publisher Copyright:
© 2016

Keywords

  • alumina delta-on-alumina-delta
  • alumina delta-on-highly crosslinked polyethylene
  • cementless total hip arthroplasty
  • osteolysis
  • polyethylene wear
  • young patients

Fingerprint

Dive into the research topics of 'Alumina Delta-on-Highly Crosslinked-Remelted Polyethylene Bearing in Cementless Total Hip Arthroplasty in Patients Younger than 50 Years'. Together they form a unique fingerprint.

Cite this